- Measurement Range:0-40KPa......0-3MPa
- Accuracy:± 0.2%
- Output:4~20mA, 4~20mA+HART, MODBUS RS485
- Protection Level:IP65/IP67
- Explosion -Proof:NEPSI EXDB IIC T6 GB


-
Wide measurement compatibility: Measuring medium: gas, vapor, liquid can be a variety of occasions.
-
high measurement accuracy: monocrystalline silicon principle can be as high as 0.1% FS or 0.2% FS;
-
fast response time: amplifier components damping constant of 0.1s; sensor time constant of 0.1s ~ 1.6s, depending on the range and range ratio;
-
self-diagnostic function: if the sensor or circuit failure, the automatic diagnostic function automatically outputs 22.0mA, which serves as a fault warning.
The flange mounted differential pressure transmitter is used to measure the pressure, level or density of liquid, gas or vapor. The use of monocrystalline silicon differential pressure sensing element or fully sealed capacitor, so that the pressure measurement has a high measurement accuracy at the same time to ensure excellent stability and reliability, the pressure by the capillary tube within the tank filled with silicone oil (or gas liquids) to the main body of the color changer, and then by the transmitter body of the x-chamber and the amplifier circuit board, will be converted to pressure or differential pressure 4 ~ 20mA DC signal output. Users can calibrate, set and configure the transmitter through HART communication hand manipulator. Widely used in chemical industry, metallurgy, water conservancy, electric power, petroleum and other occasions.
Model | AED 27 |
Accuracy | ±0.2% |
Output | 4~20ma, 4~20mA+HART, ModBus RS485 |
Power supply | 12~32VDC |
Ambient Temperature Effect | ≤±0.1%F.S/10°C |
Long-term Stability | ≤±0.2%/URL (12 months) |
Static Pressure Effect | ≤±0.1%/range/1MPa |
Response Time | 0.25s |
Power Supply Effect | ≤±0.005%/URL/V |
Vibration Effect | ≤±0.25%/URL/g |
Working Temperature | Normal temperature silicone oil: -40~150°C |
High temperature silicone oil: 15~315°C | |
Fluorine oil: -45~205°C | |
Vegetable oil: 10~80°C | |
Storage Temperature | -40~85°C |
Storage Humidity | ≤95%RH |
Protection Level | IP65/IP67 |
Explosion-proof Level | NEPSI Ex db IIC T6 Gb |
Process Connection | M20*1.5; G1/2; NPT1/2; NPT1/4; NPT1/2 |
Range Segment | Measurement Type | Minimum Range | Upper Range Limit | Lower Range Limit |
0-40KPa | Differential Pressure | 4KPa | 40KPa | -40KPa |
Gauge Pressure | 4KPa | 40KPa | -40KPa | |
0-250KPa | Differential Pressure | 25KPa | 250KPa | -100KPa |
Gauge Pressure | 25KPa | 250KPa | -100KPa | |
0-3MPa | Differential Pressure | 0.15MPa | 3MPa | -0.1MPa |
Gauge Pressure | 0.15MPa | 3MPa | -0.1MPa |