- Range:-0.1~ 0 ~ 40MPa
- Resolution:0.5% F.S
- Output signal:4~20mA; 1~5V; 0~10V; 0~5V; RS485
- Installation:Clamp
- Power supply:24VDC (9 ~ 36V)


-
Standard clamp connection design enables tool-free, fast installation and removal, saving maintenance time.
-
Flush diaphragm design with no dead corners meets CIP/SIP cleaning requirements for food, pharmaceutical, and other industries.
-
Made of all stainless steel material (such as SUS316L), suitable for various corrosive media environments.
-
High precision, fast response, and strong anti-interference capability ensure reliable measurement data.
-
Supports 4-20mA, HART, Modbus, and other communication protocols for easy system integration.
-
Small and lightweight, ideal for installation in tight pipeline and equipment spaces.
AEA15 Membrane pressure transmitter is a sanitary pressure transmitter for food, beverage, pharmaceutical and bioengineering industries. The product explosion-proof grade Ex db IIC T6 Gb, the maximum extent to meet the health industry in the explosion-proof area of a variety of working conditions in the measurement and display needs; the transmitter process connection part of the whole welded and polished process, no hygiene dead ends, the relevant health design in line with FDA standards. The transmitter sensitive components are all imported silicon microfusion core, direct measurement of a variety of production processes -20 ~ 180 ℃, 0 ~ 16MPa range of liquid, gas and steam pressure, stable performance, high measurement accuracy; cleaning and autoclaving without disassembly, easy to use, simple operation. The transmitter outputs standard 4-20mA current signal or 0-10VDC voltage signal.
Model Number | AEA 15 |
Measuring range | 0-35KPa......0-70MPa |
Overpressure limit | Max 140Mpa |
Process temperature | -20~85°C |
Ambient temperature | -40~85°C |
Accuracy | ±0.2% |
Power supply | 12~32VDC |
Output | 4~20mA, 4~20mA+HART, MODBUS RS485 |
Ambient temperature effect | ≤±0.2%F.S/10°C |
Long-term stability | ≤±0.2%/URL (12 months) |
Response time | 0.25s |
Protection level | IP65/IP67 |
Explosion-proof grade | NEPSI Ex db IIC T6 Gb |
Casing material | Cast aluminum alloy; SUS304 |
Diaphragm material | SUS316L; Hastelloy C; Tantalum |
Casing seal material | Nitrile rubber |