DP transmitters
DP transmitters are used to measure the level, density, and pressure of liquids, gases, or vapors, and then convert them to 4-20mADC HART current signal output. Adopting high-precision monocrystalline silicon technology, the measurement accuracy is as high as 0.075 grade, and the unique double overload protection membrane design, the unidirectional overpressure can be up to 40MPa.
  • Measurement Range:0-6kPa .... 0-40MPa
  • Accuracy:± 0.1%, ± 0.2%, ± 0.075%
  • Output:4~20mA, 4~20mA+HART, MODBUS RS485
  • Protection Level:IP65/IP67
  • Explosion -Proof:NEPSI EXDB IIC T6 GB
DP transmitters
ARTang ARTang
  • With throttling device can detect the flow of liquid, gas, steam;
  • It can directly detect differential pressure, gauge pressure, absolute pressure, and liquid level in open or closed containers;
  • Convert the measured pressure signal into 4-20mADC signal and supply it to PLC and secondary instrumentation;
  • Using digital compensation technology to compensate for temperature and static pressure, which improves the measurement accuracy;
  • High measurement accuracy up to ± 0.1% FS, special can be customized ± 0.075% FS.

DP transmitters can be used with a throttling device to measure the flow of liquids, gases and vapors, as well as directly to measure differential pressure, gauge pressure, absolute pressure and the level of liquids in open or closed vessels. It can realize the measurement from micro differential pressure to large differential pressure, from low pressure to high pressure, absolute pressure and high static pressure, and convert the measured pressure signal into standard 4-20mA DC signal output. Now it is widely used in petroleum, chemical, metallurgy, electric power, papermaking, medicine, textile, environmental protection and other industries, such as differential pressure, pressure and other process parameters of the measurement.

Technical Parameters


Model Number

AEA 18

Operating Temperature

-40~85°C

Accuracy

±0.1%; ±0.2%; ±0.075%

Storage Temperature

-40~85°C

Output

4~20ma, 4~20mA+HART, ModBus RS485

Storage Humidity

≤95%RH

Power supply

12~32VDC

Protection class

IP65/IP67

Ambient Temperature Effects

≤±0.1%F.S/10°C

Explosion-proof

NEPSI Ex db IIC T6 Gb

Long Term Stability

≤±0.2%/URL (12 months)

Process connection

M20*1.5; G1/2; NPT1/2; NPT1/4; NPT1/2

Static Pressure Effect

≤±0.1%/range/1MPa

Housing material

Cast Aluminum Alloy; SUS304

Response Time

0.25s

Diaphragm material

SUS316L; Hastelloy C

Power Supply Impact

≤±0.005%/URL/V

Sensor seal material

Nitrile Rubber; Fluorosilicone; Teflon PTFE

Vibration Effects

≤±0.25%/URL/g

//



Applications of Differential Pressure transmitter

Hydraulic Systems: DP transmitters are used in hydraulic systems to monitor pressure differences and ensure smooth operation and safety.

Steam Systems: DP transmitters are employed in steam systems to measure the pressure difference across steam traps and identify malfunctioning traps.

Air Handling and HVAC: In ventilation systems, DP transmitters are used to monitor air pressure differences, filter conditions, and airflow.

Environmental Monitoring: DP transmitters are used in environmental monitoring equipment to measure pressure changes in weather systems or natural gas pipelines.


Measurement Range

Measurement Range

Measurement Type

Minimum Range

Upper Range Limit

Lower Range Limit

Overpressure Limit Value

0-6KPa

Differential Pressure

1KPa

6KPa

-6KPa

16MPa

High Static Pressure

1KPa

6KPa

-6KPa

25MPa

0-40KPa

Gauge Pressure

1KPa

6KPa

-6KPa

16MPa

Differential Pressure

4KPa

40KPa

-40KPa

16MPa